Article library

Solar planning guides

Practical articles that connect small solar goals to parts, numbers, limits, and safety decisions.

22 guides
System flow diagram with every stage highlighted, representing the ordered sequence of measurements used to isolate a fault.
Troubleshooting8 min read

Your Solar System Underperforms: A Diagnostic Order of Operations

A measurement-based decision tree for diagnosing four common solar complaints, with the ordered tests that isolate voltage drop, panel faults, mismatch, and charge-acceptance limits.

Read guide
System flow diagram for a small continuous load, highlighting the PV array and battery as the stages that dominate worst-month sizing.
Project Blueprint9 min read

Solar for Cameras, Gates, and Remote Sensors: Sizing for Tiny Loads

Why very small 24/7 solar loads are harder to size than big ones: worst-month sizing, controller self-consumption, the December problem, oversizing the array over the battery, and freeze protection.

Read guide
System flow diagram with every stage highlighted, representing equipment grounding applied across the whole system rather than at one point.
Safety9 min read

Grounding and Bonding a Small Off-Grid DC System

Equipment grounding versus system bonding versus earthing, floating versus bonded DC negatives, and why local code should override generic advice here.

Read guide
System flow diagram highlighting the PV array stage, where tilt and orientation determine how much energy reaches the system.
Planning7 min read

Panel Tilt and Orientation: Optimising for the Season That Matters

Why off-grid systems should size tilt for the worst month rather than the annual average, latitude-based tilt rules and their limits, and ground versus roof mount tradeoffs.

Read guide
Bar chart of manufacturer charge cutoff temperatures in degrees Celsius: Victron at 5, Battle Born and Discover at 0, and EG4's cell-level trip at minus 5.
Components8 min read

Charging LiFePO4 Below Freezing: What Actually Goes Wrong

The lithium plating mechanism behind LiFePO4's cold-charging limit, how manufacturer cutoffs differ, and how lead-acid's very different freezing-point constraint compares.

Read guide
Bar chart comparing conductor cross-section in square millimetres for 8, 6, 4, and 2 AWG copper against the smaller metric sizes often substituted for them.
Components8 min read

PV Wire, MC4 Connectors, and Battery Cable: Choosing the Right Conductor

How PV wire, USE-2, THHN/THWN-2, welding cable, and marine battery cable differ, and why MC4 connectors from different brands are a documented fire hazard.

Read guide
System flow diagram highlighting the charge controller between array and battery, illustrating where MPPT conversion recovers energy that PWM discards.
Components8 min read

MPPT vs PWM Charge Controllers: When the Extra Cost Pays for Itself

What PWM and MPPT controllers actually do to panel voltage, when the price gap between them is worth paying, and when MPPT stops being optional.

Read guide
Schematic comparing two 36 volt panels wired in series producing 72 volts at 5 amps, against the same two panels in parallel producing 36 volts at 10 amps.
Wiring8 min read

Wiring Panels in Series or Parallel: Voltage, Current, and Shade Tradeoffs

How series and parallel panel wiring change voltage, current, wire size, and shading behavior, and when parallel strings need their own fuses.

Read guide
System flow diagram with the inverter stage highlighted between the battery bank and the loads.
Components11 min read

Sizing an Inverter: Why the Biggest One Is Usually the Wrong Choice

Continuous versus surge rating, the hidden cost of idle draw, and why a 2000 W inverter can waste more power than it delivers on a small solar system.

Read guide
Bar chart of a worked daily load table showing router, lighting, laptop charging, and tool charging totalling 682 watt-hours per day.
Planning10 min read

The Load Audit: The One Step That Decides Every Other Number

How to build a real load table with watts, hours, and duty cycle, measure actual draw instead of trusting nameplate ratings, and set a design buffer without padding a solar system three times over.

Read guide
Line chart of a maintenance log trend showing daily harvest declining from 640 to 470 watt-hours over six months as soiling accumulates.
Maintenance7 min read

A Maintenance Log for Small Solar Systems

What to record in a solar maintenance log and why each entry has diagnostic value later, with chemistry-specific intervals, torque re-checks, and a usable log template.

Read guide
System flow diagram highlighting the PV array stage, where partial shading disproportionately reduces output.
Planning8 min read

Solar Panel Placement: A Simple Shading Check Before You Mount

Why partial shading costs disproportionately more than the shaded area suggests, what bypass diodes do and do not fix, and how to survey a site for shade without special equipment.

Read guide
Bar chart comparing the current drawn by a 1200 watt load at 12, 24, and 48 volts: 100 amps, 50 amps, and 25 amps respectively.
System Design8 min read

12 V vs 24 V Solar Systems: When Higher Voltage Helps a Small Build

Why current, not power, sets wiring cost, with a worked comparison of a 1200 W load at 12 V, 24 V, and 48 V showing current, wire size, and copper cost.

Read guide
System flow diagram with the charge controller stage highlighted between the PV array and the battery bank.
Components9 min read

How to Size a Solar Charge Controller for a Small Off-Grid Project

Size a charge controller by array current and array voltage, including the cold-weather Voc rise that turns a nameplate-safe array into an overvoltage fault.

Read guide
System flow diagram highlighting battery and controller, the stages whose connection order matters at first power-on.
Safety8 min read

DIY Solar Pre-Flight Checklist: What to Verify Before First Power-On

A sequential commissioning procedure for small solar systems: polarity, torque, fuse ratings, energization order, and what to check at one hour, one day, and one week.

Read guide
Bar chart of usable energy from a nominal 1200 watt-hour battery by chemistry: 600 watt-hours for lead-acid at 50 percent depth of discharge, 960 for LiFePO4 at 80 percent, 1200 at 100 percent.
Calculations9 min read

How to Size a Small Solar Battery Bank Without Overspending

A sizing method for small off-grid battery banks: how days of autonomy drive cost, why an oversized lead-acid bank can shorten its own life, and how to match array output to charge acceptance.

Read guide
Bar chart of remaining charge after five unoccupied winter months: LiFePO4 retains about 88 percent, AGM about 90 percent, flooded lead-acid about 59 percent.
Project Blueprint9 min read

Cabin Solar Backup Power Wall: What to Plan Before Mounting Gear

Planning a cabin power wall for a building nobody occupies most months: self-discharge, freeze risk, seasonal battery chemistry, equipment layout, ventilation, surge loads, and the generator question.

Read guide
System flow diagram of an RV solar system with every stage highlighted, marking the full path that must be fused, routed, and strain-relieved.
Project Blueprint9 min read

RV Solar Wiring Checklist: Fuses, Disconnects, and Cable Routes

A sequential RV solar wiring checklist built on ABYC E-11: engine-space derating, the 7-inch fuse rule, disconnect placement, and chafe protection.

Read guide
System flow diagram of a complete shed solar system from PV array through controller, battery, and inverter to the loads.
Project Blueprint8 min read

A Practical Starter Plan for a Shed Solar System

A complete shed solar system derived step by step: load table, battery, array, controller, inverter, wire gauge, and fuse sizing, with every number worked on the page.

Read guide
Bar chart showing a 1280 watt-hour battery reduced to 1024 watt-hours after 80 percent depth of discharge and 922 watt-hours after inverter losses.
Calculations8 min read

Battery Runtime Math: Why Nameplate Watt-Hours Are Not the Whole Story

How depth of discharge, inverter loss, idle draw, Peukert's effect, temperature, and aging turn a battery's nameplate watt-hours into a much smaller honest runtime number.

Read guide
System flow diagram highlighting battery and inverter stages, the two places where most RV solar disappointments originate.
Troubleshooting9 min read

Seven RV Solar Mistakes That Make Small Systems Feel Weak

Seven RV solar mistakes explained by mechanism, symptom, and confirming measurement — from undersized cable and wrong charge profiles to alternator charging assumptions that fail on LiFePO4.

Read guide
Line chart of voltage drop percentage against one-way run length for 10, 6, and 2 AWG copper at 12 volts and 20 amps, showing 10 AWG passing 3 percent within about 7 feet.
Wiring8 min read

Voltage Drop in Low-Voltage Solar Wiring: A Plain-English Guide

What voltage drop physically is, why it dominates 12 V and 24 V design, how to measure it with a multimeter, and the three levers that actually fix it.

Read guide